Xenus Plus User Guide Operational Theory
Copley Controls 41
2.10.6: 800-1808 J7: Drive and MACRO Network Status Indicators
800-1808 J7 Axis A/B: Drive Status Indicators
800-1808 indicator color/blink codes are described below.
Drive OK and enabled. Will run in response to reference inputs or MACRO commands.
Drive OK but NOT-enabled. Will run when enabled.
Positive or Negative limit switch active. Drive will only move in direction not inhibited by
limit switch.
Green flash twice
followed by a pause
STO is active, One or both STO inputs are de-energized. The drive is hardware & software
enabled but the PWM outputs cannot produce current in the motor when STO is active.
Transient fault condition. Drive will resume operation when fault is removed.
Latching fault. Operation will not resume until fault is cleared or drive is Reset.
800-1808 J8 Axis A/B NET Indicator: MACRO Network Status
MACRO network has not been detected.
MACRO network detected and has disabled drive.
MACRO network detected and is trying to enable drive. This condition can occur while the
AMP LED shows any of its valid color combinations. This LED must be green for the AMP
LED to become green.
MACRO network errors have been detected.