3.8: Digital Inputs
XEL/XPL/XML
Schmitt trigger w/ RC filter,
24Vdc max
Non-isolated line receiver w/
RC filter, programmable as 4
single-ended or 2 differential
Single-ended
Opto-isolated, bi-polar, 2
groups of 4 with common for
each group
Digital
Programmable 0 - 10,000 ms
Digital
Programmable 0 - 10,000 ms
Digital
Programmable 0 - 10,000 ms
IN1 enable
IN2~IN15 programmable
Note: Inputs 3&4 and 5&6 can be programmed to function as differential pairs as digital command
inputs.
XE2/XP2/800-1782/800-1808
Schmitt trigger w/ RC
filter, 24Vdc max
Non-isolated line
receiver w/ RC filter,
programmable as 4
single-ended or 2
differential Single-
ended
Opto-isolated, bi-
polar, 2 groups of 4
with common for each
group
Motor overtemp
signals on feedback
connectors
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
All programmable
Note: 800-1782 does not utilize IN21-22 and dedicates IN16-19 to optical limit switches of motors.