Parameter Dictionary Parameters
5 If set, exit table in forward direction.
If set, use the Camming Internal Generator. The internal generator runs at the constant
velocity programmed in Camming Master Velocity (0x109).
If clear, use digital command input as configured in using Copley’s CME 2 software camming
controls or Input Pin States (0xA6).
7 If set, run tables stored in RAM. If clear, use tables stored in the flash file system.
Input number to use as Cam Trigger. Note: a value of 0 selects IN1, 1 selects IN2, etc.
None (Continuous): The active Cam Table is repeated continuously.
Use Input, Edge: The active Cam Table begins executing on the rising edge of the
input pin selected by bits 8-11.
Use Input, Level: The active Cam Table will run as long as the input selected by bits
8-11 is high.
3 Use Master (Secondary) Encoder Index: The active Cam Table is executed when
the drive receives an index pulse from the Master encoder. Index pulses received
during execution are ignored.
Never trigger. This can be used to stop a CAM currently in progress
Camming delay, forward motion. This gives the delay (in master encoder counts)
used when entering a cam table in the forward direction. Units: master command
counts.
Camming delay, reverse motion. This gives the delay (in master encoder counts)
used when entering a cam table in the reverse direction. Units: master command
counts.
Writing any value to this parameter will cause any CANopen PDO objects configured
with type code 254 to be sent. This parameter is primarily useful for triggering a PDO
from within a CVM program.
Reading this parameter does not return any useful information.
Camming Master Velocity. Constant velocity of the Camming Internal Generator.
Units: 0.1 counts/s.
Captured Home Position. Provides the position that the axis was in when an input pin
configured as a home switch input became active. Configured by setting bits in the
Position Capture Control Register (0x6C). Status of the captured data can be
checked in the Position Capture Status Register (0x6D). Reading this variable resets