Parameter Dictionary Parameters
Debounce time for general purpose input 19.
Debounce time for general purpose input 20.
Debounce time for general purpose input 21.
Debounce time for general purpose input 22.
Debounce time for general purpose input 23.
UV configuration. This parameter is used to configure the drive when running in UV
mode (desired state 5). Bit-mapped as follows (undocumented bits are
reserved for future use):
Define the source of the UV command inputs:
Analog reference inputs (for drives with two analog reference pins).
Directly set over the serial/network interface.
Define the format of the UV inputs:
120 degree current commands.
90 degree current commands.
Angle/Magnitude form. U input gives magnitude, V gives angle.
If set, the value of the Motor Hall Offset (0x4F) is added to the UV angle
If set, the drive will use field oriented control. Normally FOC is disabled in UV mode due to
the ambiguity of the phase angle with zero inputs. This is best used when running in
angle/magnitude format.
U input when running in UV mode. This parameter can be used to read the
calculated U value, or to set a U value when the UV inputs are being directly
set over the serial/network interface.
V input when running in UV mode.
Raw counter value from pulse & direction input hardware. This can be read
when running in any mode, not just pulse & direction modes.
This parameter can be written also, but should not be written when the amp
is being driven by the pulse & direction inputs. Writing in that mode will
cause the amp to treat the change in the counter as real pulse inputs
resulting in possible unexpected motion.